top of page

KAWLPHETHA CHUANGLIAM LAKA INVENHIM PAWIMAWHNA : I IN LEH SUMDAWNNA HMUN VENHIM NAN

  • Writer: Ten Joules
    Ten Joules
  • Feb 18
  • 4 min read

Updated: Mar 29




KAWLPHETHA, Mizo ten Current kan tihmai thin leh a chuangliam emaw current short emaw kan tihmai thin in a thil pawi tak a thlen theih te leh a thlen thin te chu kan hretheuh awm e. Electrical system kaihhnawih a kan lo tawn tak zawng zawng ah khan kan hriat chhuah tak chu, electrical venhimna lama kanlo fimkhur tawk loh lutuk  na in nasa taka chhiatna a thlen theih dan ani. Mitam tak  chuan heng surge protectors,voltage stabilizers leh circuit breakers te ang chi invenna khawl dah a pawimawh zia kan ngaihthah a, electric a chhiat  emaw hmanrua a chhiat hnuah chauh a pawimawh zia an hrechhuak thin. He blog ah hian  electrical venhimna pawimawh zia leh hmalakna dik chuan current vang a thilpawi zawk leh  sumtamtak kan chan theih phahna laka inven dan leh inven a pawimawh zia te kan tarlang dawn ani.


1.Power Surges laka invenna :

Power Surges kan tih chu thawk leh khat a voltage sang thut/ current chuangliam rawn insiam belh thut sawina ani a. Heng ṭek tla vang te,wiring diklo leh Power Grid lam atanga Voltage inthlak danglam thut vanga thleng thei ani. Heng voltage sang thut te hian current short thlenin kan TV, Fridge leh Computer te a tichhe thei a. Mizoramah, clients tamzawk ten "Surge Protector" an neihloh vang a an khawl hlu tak tak anlo chan fo tawh a.Amaherawhchu, Surge Protection System tha tak chuan, kan hmanrua leh khawl tha te lo veng in,inrinloh laia voltage sang thut lakah inralring rengin anlo awm a, keini thlamuang taka awmin kan khawl tha te nunna min pawhsei sak thei ani.


2.Overvoltage leh Undervoltage awm thei laka invenna :

Kan khawl te, current hmang chi hrim hrim te hian an thawh tur ang an thawh theih nan hian current emaw voltage mamawh zat an nei theuh a.

Overvoltage: Kan tih chu khawl in a mamawh aia tam current a dawn hi ani a,khawl in a mamawh aia tam current emaw voltage a dawn chuan a khawl a khan tuarlo in a then ah phei chuan a part thenkhat te tikang in a chhiat phah thei ani.

Undervoltage: Vethung chuan khawl in a mamawh zat ang aia tlem current emaw voltage a dawn hi ani a,khawl in a mamawh ang zat aia tlem a current dawng anih chuan a thawh theih nan current dang amahten alo lak belh anga, a thawh dan tur pangai aia thawk rim zawkin a chhiat phah zung zung thei ani

Heng Overvoltage leh Undervoltage vennan hian clients tamtak te chu Voltage Protector leh Automatic Stabilizers te hi kan lo vuah sak tawh a, sum tamtak an chan theihna tur kanlo ven sak thin ani.


3.Circuit Breakers: Current lama felhlel awm thei laka invenna hmasa ber:

Circuit Breaker, MCB kan tihmai thin hi current lam a felhlel awm thei laka invenna hmasa ber niin,current overload emaw current short a awm tih a hriat rual in he khawl hian current supply alo pawt chat vat thin a, kangmei chhuak thei lakah te min venghim thei ani.In leh Sumdawnna hmun hrang hrang ah te, Fuse System hlui tak tak hmang hmuhtur hi anla awm fo mai a,heng hian Modern Circuit Breaker(MCB) kan tihte hi an tluk lo hle a, Fuse System hlui tawh hmang kanla awm anih chuan a ranglam a MCB vuah vat hi a finthlak zawk hle ani.


4. Shock laka invenna turin Residual Current Devices (RCDs) :

Current Leak in mihring a man hi thil hlauhawm leh tihbaiawm tak, nunna hial chan phah thei thil thlen tu ani a, tui awm tamna hmun; bathroom te choka ah te hian current leak hi a awm duh em em a.Amaherawhchu, mumal taka Residual Current Device (RCDs) kan vuah chuan , he khawl hian current leak hrim hrim a awm tih a hriat rualin current supply lo pawtchat vatin, current leak awm belh zel tur alo veng a,kan nunna min chhanhim sak thei ani. Current vanga thihna case kan hmuh tam zawk hi RCD vuah thatloh vang te anni chawk a,mumal takin RCD lo vuah nita sela chuan thihna an pumpelh thei zawk ngeiin a rinawm.



5.Sumdawnna liantham leh Industry te venhimna :

Sumdawnna lian leh Industrial Facility angah te hian current lama felhlel a awm palh hlauh chuan loss tamtak a thlen thei a, heng laka invennan hian Mizorama sumdawnna hmun hrang hrang ah te hian khawl chi hrang hrang; Overcurrent relays, Lightning arresters leh Phase failure protection device te kanlo vuah sak tawh thin a, an vuah hma a current lam fello vanga an channa leh harsatna tamtak kanlo sutkian sak tawh ani.


6.Current vanga kangmei chhuak tur laka inven dan:

Kangmei chhuak tamtak te hi circuit overload vang te, circuit short vang te leh wiring mumallo leh tha tawklo ina a thlen ani a.Current chianloh vanga kangmei chhuak tur kan ven theih nan hian Arc Fault Detection Device (AFDDs) te vuah a, Earthing (current chuangliam a hlauhawmloh chin a paih chhuahna) mumal tak kanneih a ngai ani.Clients tamtak current vanga kangmei chhuak thei laka an inven theih nan AFDDs te leh wiring tha te kanlo vuah sak fo tawh thin ani.

Mi tam takin thil pawi thleng tur zawng zawng a thlen hnu ah lo inven that a pawimawh zia an hrechhuak chauh thin a,mahse thilpawi thleng tur thlen hma a lo inven lawk tluk hi a awmlo ani.Kum tam tak kan Firm in a kanlo experience tawh atangin Mizoramah ngei pawh lo inven lawk a hlawkthlak zia kanlo hmu fo tawh a. Chuvangin sum tamtak I chan theihna turlaka invennan leh nunna hlutak I chhanhim theih nan heng; Surge Protectors,Voltage Stabilizers, Circuit Breakers leh a dang tamtak te hi kan hnen atangin tlawm si tha si in lo lei ta che. Min duhsak a minlo pan a nih chuan kan mithiam kawl tamtak ten i duhna hmunah tak anlo vuahsak thlap dawn che ani.

 
 
bottom of page